Page 94 of 101
DWG ID: 181-0101-00A
Date: 2003-09-26
A telemetry beacon is sent every n*10 s. If n = 0, the beacon is disabled. The telemetry
beacon is a UI frame sent to BEACON. If there is a current UNPROTO digipeat path, it
will be used to transmit the telemetry beacon.
The data in the UI frame is in the form:
“T#nnn,an0,an1,an2,an3,an4,an5,an6,an7,bbbbbbbb”, where:
•
“nnn” is a decimal count for the telemetry beacon and is incremented each time the
beacon is sent. When first used, or after the unit is reset, the beacon counter begins at
001 (T#001). After reaching 999 (T#999), the counter cycles around to 000 (T#000).
•
“an0", ”an1", “an2", ”an3", etc., are the decimal readings on the corresponding
analog inputs.
•
“bbbbbbbb” is the binary reading of the 8 inputs, where “b” = “1" means a Logic
High on the pin and ”b" = “0" means a Logic Low on the pin. The first ”b" in the
string of 8 binary digits is the most significant bit, and the last “b” is the least
significant bit.
See also: analog, range
TEMPERAT [C|F]
Immediate
Displays the current internal temperature of the TALON. Its default output is in degrees
Celsius. Enter TEMPERAT F to change the display to degrees Fahrenheit.
TRACE {ON | OFF}
default OFF
When ON, all received frames are displayed in their entirety, in hexadecimal, including
all header information. All packets which are eligible for monitoring also will be
displayed in normal text.
TRANS
immediate
This command causes immediate exit from Command Mode into Transparent Mode. The
current link state is not affected. There are no special editing characters, all characters are