Page 74 of 101
DWG ID: 181-0101-00A
Date: 2003-09-26
HEADERLN {ON | OFF}
default ON
When ON a carriage return is output to the terminal between the header and text of
monitored packets. This causes the packet header and time stamp (if on) to be displayed
on one line, with the packet text displayed below it on the next line. When receiving
packets addressed only to you (MONITOR and/or MCON OFF) this parameter does not
apply. When OFF, the data will be on the same line as the header.
See also: cstamp, mcon, monitor, and mstamp
HELP [command]
Immediate
Entering the word “HELP” alone, without any argument, will generate a display listing
all commands available in the TALON.
When the name of a command is entered also (e.g., HELP CONVERS), a brief
description of that command will be displayed. A wild card also can be used; entering
“Help C*” will display brief descriptions of all commands beginning with C.
HELP can also be called by entering “?”.
HID {ON | OFF}
default ON
When ON, an ID packet will be sent every 9.5 minutes, provided that packets are being
digipeated through your station. This command should be ON if digipeating is enabled. If
OFF, periodic identification packets will not be sent.
See also: digipeat, id, and myalias
ID
Immediate
When this command is entered an identification packet will be transmitted. This
command may be used to insure that your station identification is the last transmission
before taking the station off the air.