Country-
spec. Set-
tings
Level Display/
Setting
Action in this menu/meaning
4
1
2
3
4
Localization
Status
1. Select the current date and enter the time or press the button "Sync
with client device now".
2. Select a time zone.
3. Activate the NTP server and assign a name.
4. Obtain NTP server settings from DHCP.
5. Specify the temperature unit.
6. Confirm the action field.
4
1
2
3
4
Miscellaneous
1. Enter the device name.
2. Enter the degree of longitude and latitude of the installation loca-
tion.
3. Enter the plant ID.
4. Confirm the action field.
4
1
2
3
4
DC Parameter
Input screens for generator and string collector.
4
1
2
3
4
String Combiner
NOTE: Option to configure a string combiner.
String combiner monit-
oring
Status
F
Select monitoring function with connected string combiner.
Serial number of the
assigned string com-
biner
F
Enter serial number after installation of the device.
NOTE: The serial numbers of the string combiners that are not
directly connected to the device are entered in the segment
controller.
Baud rate & number of
data acquisition units
9600
8n1
1. Specify transmission and detection intervals.
2. Enter the number of data acquisition units as necessary.
Unit address
Unit channels
1. Specify IP address of the string combiner.
2. Specify the number of monitored strings.
3. Confirm the action field.
4
1
2
3
4
Constant voltage con-
trol
NOTE: Option to disable the MPP seek mode in order to oper-
ate the device with a constant DC voltage.
NOTE: When constant voltage operation and "Q on Demand"
operation are activated, feedback can occur on the PV gener-
ator. Please observe the module manufacturer's instructions
and approval.
Constant voltage
Page 12] [V] /
1 [V]
F
Set value for constant voltage control.
Constant voltage mode
Off | On
1. Activate or disable the constant voltage.
2. Confirm the action field.
4
1
2
3
4
DC starting voltage
Page 12] [V] /
1 [V]
NOTE: The device begins feed-in as soon as this DC voltage is
present.
1. Set the starting voltage.
2. Confirm the action field.
9 | Configuration and operation
Manual
KACO blueplanet 100 TL3
Page 48
EN