19
on front side of the generator.
6
Function Switch
(CONT./ FOOT SW.)
Selecting the operation way by auto or foot sw.
7
Roller Speed Adjusting
Knob (SPEED A)
The knob for adjusting the feeding speed of
sealing roller and puller roller. It should be
adjusted to match the feeding speed of tool horn.
The feeding speed will be increased as the knob is
rotated clockwise.
8
Horn Speed Adjusting
Knob (SPEED B)
The knob for adjusting the speed of tool horn. The
speed setting used depends on the materials,
pattern of roller, pressure of roller and the power
setting of horn vibration. It should be adjusted to
match the feeding speed of roller if possible.
Otherwise, the tool horn surface will be easily
scratched by the roller.
9 Fuse
10A/250V
φ
6.3×32 mm fuse inside the fuse
holder each.
10 Fan
Guard
To prevent the human body touching the AC fan.
11 Enclosure
To support and fix the electrical parts of the
generator.
12
Cable with 4P Connector
Transmission of electrical power from the
transformer unit to the generator.
13 2P Output Socket
Transmission of high-voltage ultrasonic energy to
the booster via cable connection.
14 10P Control Socket
Transmission of control circuit signals via cable
connection.
Содержание KS-2010
Страница 12: ...11 ...
Страница 13: ...12 ...
Страница 22: ...21 ...
Страница 23: ...22 ...
Страница 31: ...30 6 4 Wiring Diagram A MAIN WIRING DIAGRAM A 1 KS 72 ...
Страница 32: ...31 A 2 KS 85 ...
Страница 38: ...37 FUSE FUSE B GENERATOR CIRCUIT DIAGRAM KS 72 KS 85 KS 2010 KS 3010 ...