JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
135
5.10.2
Setup without MacTalk
If MacTalk is not used for setting up parameters and registers related to the under voltage
feature it must be done as follows.
The motor contains a number of registers which can be accessed from various protocols
depending at which options the motor has.
Protocols available are for example Ethernet (EthernetIP, PROFINET etc.) and CAN-
open, Modbus or the MacTalk protocol.
Each field in MacTalk described earlier in this chapter is accessing a register in the motor.
The registers that are relevant for the under voltage feature are:
R98
MIN_BUSVOL
The voltage level that defines when an under voltage
situation is present at the P+ (main power).
See also:
R124
SetupBits
SetupBitsThe 3 bits that define what action should
be taken in case of an under voltage situation.
Bit 21
: Under voltage -> Set error bit
Bit 22
: Under voltage -> Stop controlled and go to
passive
Bit 23
: Under voltage -> Set velocity to 0
See also:
If none of the above bits are set the motor will con-
tinue to run when the main power (P+) is back.
Содержание MIS17 Series
Страница 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 57: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 57 3 Functional Safety ...
Страница 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 77: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 77 4 Using MacTalk ...
Страница 165: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 165 7 Error Handling ...
Страница 177: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 177 8 Registers ...
Страница 235: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 235 9 Building Sequential Programs ...
Страница 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 309: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 309 12 Modbus interface ...
Страница 313: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 313 13 Stand alone electronics ...
Страница 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Страница 319: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 319 15 Technical Data ...
Страница 325: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 325 15 5 Torque Curves ...
Страница 338: ...338 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 15 8 Trouble shooting guide ...
Страница 340: ...340 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 16 1 Cables ...
Страница 345: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 345 17 Appendix ...
Страница 355: ...JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 355 18 Declarations ...
Страница 362: ...362 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x 18 4 TÜV certificate ...