CAUTION:
The services gateway cannot be powered from AC and DC power supplies
simultaneously. The first type of power supply detected by the services gateway when
initially powered on determines the type of power supply allowed by the services
gateway. All installed power supplies of the other type are disabled by the services
gateway. If you install a power supply of the other type while the services gateway is
operating, the services gateway disables the power supply and generates an alarm.
When the services gateway is powered by standard-capacity AC power supplies, the services gateway
contains either three or four AC power supplies, located at the rear of the chassis in slots PEM0 through
PEM3 (left to right). Each power supply provides power to all components in the services gateway. When
three power supplies are present, they share power almost equally within a fully populated system. Four
power supplies provide full power redundancy. If one power supply fails or is removed, the remaining
power supplies instantly assume the entire electrical load without interruption. Three power supplies
provide the maximum configuration with full power for as long as the services gateway is operational.
When the services gateway is powered by either standard- or high-capacity DC power supplies, or by
high-capacity AC power supplies, power distribution within the chassis is divided into zones, as described
in
.
Table 13: SRX5800 Services Gateway Power Distribution (DC or High-Capacity AC Power Supplies)
Provide Power To:
Power Supplies
Zone
•
Lower fan tray
•
IOC or SPC slots 6 through 11
•
SCB slots 1 and 2
•
PEM0
•
PEM2
Zone 0
•
Upper fan tray
•
IOC or SPC slots 0 through 5
•
SCB slot 0
•
PEM1
•
PEM3
Zone 1
shows the distribution of power from the power supplies to the chassis components
in an SRX5800 Services Gateway chassis powered by DC power supplies or high-capacity AC power
supplies.
48
Содержание SRX 5800
Страница 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Страница 23: ......
Страница 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Страница 111: ...LEDs 112 ...
Страница 121: ...Port and Interface Numbering 122 ...
Страница 127: ...Port and Interface Numbering 128 ...
Страница 161: ......
Страница 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Страница 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Страница 205: ......
Страница 261: ......
Страница 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Страница 365: ...Figure 143 Installing an SPC 366 ...
Страница 367: ...368 ...
Страница 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Страница 423: ......
Страница 457: ......
Страница 473: ...475 ...
Страница 476: ...Restricted Access Area Warning 478 ...
Страница 483: ...485 ...
Страница 496: ...Jewelry Removal Warning 498 ...
Страница 499: ...Operating Temperature Warning 501 ...
Страница 509: ...DC Power Disconnection Warning 511 ...
Страница 513: ...DC Power Wiring Sequence Warning 515 ...
Страница 516: ...DC Power Wiring Terminations Warning 518 ...
Страница 519: ...DC Power Disconnection Warning 521 ...
Страница 523: ...DC Power Wiring Sequence Warning 525 ...
Страница 526: ...DC Power Wiring Terminations Warning 528 ...