NOTE:
•
You must install four high-capacity PEMs with two inputs for each PEM.
•
You must install atleast one IOC3 and four SPC3s in each power zone.
•
You must have the third SCB in Slot 6.
•
SCB4 is not supported.
•
You can install IOC3 in slot 11 only when the ambient temperature is configured to
25° C.
•
Dual Routing Engines is optional.
•
You cannot install SPC3 in slot 11.
•
In chassis cluster if you configured dual control links, then each power zone must have
one control link.
•
You must power-cycle the SRX5800 Services Gateway after the configuration.
Table 39: SRX5800 Services Gateway Power Requirement with 8xSPC3 and 3xIOC3
Power Budget at
Ambient
Temperature
(25° C)
Power budget
(with 25° C
config)
Power Budget
(default)
Part Number
Chassis Component
Zone
320 W
320 W
320 W
SRX5800-HC-FAN
High-capacity cooling
system (Upper Fan
Tray)
Zone
1
614.5 W * 4
=2458 W
615 W * 4
=2460 W
650 W * 4
=2600 W
SPC3
SPC - slots 0 through 3
511 W * 2
=1022 W
511 W * 2
=1022 W
607 W * 2
=1214 W
IOC3
IOC - slots 4 and 5
245 W
275 W
275 W
SCB3 with RE2
SCB 0
175
Содержание SRX 5800
Страница 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Страница 23: ......
Страница 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Страница 111: ...LEDs 112 ...
Страница 121: ...Port and Interface Numbering 122 ...
Страница 127: ...Port and Interface Numbering 128 ...
Страница 161: ......
Страница 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Страница 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Страница 205: ......
Страница 261: ......
Страница 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Страница 365: ...Figure 143 Installing an SPC 366 ...
Страница 367: ...368 ...
Страница 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Страница 423: ......
Страница 457: ......
Страница 473: ...475 ...
Страница 476: ...Restricted Access Area Warning 478 ...
Страница 483: ...485 ...
Страница 496: ...Jewelry Removal Warning 498 ...
Страница 499: ...Operating Temperature Warning 501 ...
Страница 509: ...DC Power Disconnection Warning 511 ...
Страница 513: ...DC Power Wiring Sequence Warning 515 ...
Страница 516: ...DC Power Wiring Terminations Warning 518 ...
Страница 519: ...DC Power Disconnection Warning 521 ...
Страница 523: ...DC Power Wiring Sequence Warning 525 ...
Страница 526: ...DC Power Wiring Terminations Warning 528 ...