Ground the QFX5220-128C
To connect earth ground to a QFX5220-128C:
1. Use two SAE 10-32 x 0.25 in. screws with number10 split-lock washers (not provided) to secure the
grounding lug and attached cable (not provided) to the FRU panel of the chassis. The posts on the
grounding lug should point to the right. See
Figure 47: Connecting a Grounding Cable to a QFX5220-128C
g051191
2. Connect the remaining end of the grounding cable to a proper earth ground, such as the rack in which
the switch is mounted.
3. Dress the grounding cable and ensure that it does not touch or block access to other device components
and that it does not drape where people could trip over it.
Connect Power to the QFX5220-128C
The QFX5220-128C is shipped from the factory with four power supplies. Each power supply is a
hot-removable and hot-insertable field-replaceable unit (FRU) when the second power supply is installed
and running. You can install a replacement power supply in either of the two slots next to the fan modules
without powering off the switch or disrupting the switching function.
129
Содержание QFX5220
Страница 1: ...QFX5220 Switch Hardware Guide Published 2019 11 07 ...
Страница 18: ......
Страница 77: ......
Страница 107: ......
Страница 148: ......
Страница 172: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the QFX5220 179 ...
Страница 173: ......
Страница 182: ......
Страница 206: ...Restricted Access Warning 213 ...
Страница 221: ...Jewelry Removal Warning 228 ...
Страница 224: ...Operating Temperature Warning 231 ...
Страница 234: ...DC Power Disconnection Warning 241 ...
Страница 238: ...DC Power Wiring Sequence Warning 245 ...
Страница 241: ...DC Power Wiring Terminations Warning 248 ...