JunosE 10.3.2 Release Notes
66
Errata
In the
Monitoring MLD
section in
JunosE Multicast Routing Configuration Guide,
Chapter 6, Configuring Multicast Listener Discovery
, the following corrections
apply to the commands used to monitor MLD configuration:
The description of the
bgp graceful-restart
command in the
JunosE Command
Reference A to M
incorrectly states that graceful restart is enabled by default. It
also erroneously states that using the
default
keyword with the
bgp
graceful-restart
command restores the default condition, wherein graceful
restart is enabled. The correct default behavior of BGP graceful restart is that it
is disabled, which prevents the advertisement of all BGP graceful restart
capabilities. This default behavior has been applicable since the time this
command was introduced.
In addition, the Note in this command section inaccurately states that the E
Series router supports graceful restart only as a receiving peer and not as a
restarting peer. However, E Series routers have supported graceful restart as
restarting peers, in addition to functioning as receiving peers, since JunosE
Release 5.1.0.
In the
JunosE Command Reference Guide A to M
, the description of the
mpls ldp
graceful-restart reconnect-time
command incorrectly states that the
no
version restores the default value of 120 seconds. The correct default value is
140 seconds.
The description of the
neighbor graceful-restart
command in the
JunosE
Command Reference N to Z
incorrectly states that graceful restart is enabled by
default. The correct default behavior is that graceful restart is disabled. This
default behavior has been applicable since the time this command was
introduced in JunosE Release 7.1.0.
The syntax of the
show icr-partitions
command in the
JunosE Command
Reference Guide N to Z
incorrectly states the following:
show icr-partitions [ brief ] [
filter
]
The correct syntax for this command is as follows:
show icr-partitions [ backup | dormant | master | summary ] [
filter
]
where:
backup—Displays the total number of backup ICR partitions configured on
the router
dormant—Displays the total number of dormant ICR partitions configured
on the router
master—Displays the total number of master ICR partitions configured on
the router
summary—Displays a summary of all ICR partitions configured on the
router
filter
—See Filtering show Commands in the
Command Reference Guide
Содержание JUNOSe 10.3.2
Страница 8: ...viii Table of Contents JunosE 10 3 2 Release Notes ...
Страница 76: ...JunosE 10 3 2 Release Notes 68 Errata ...