JunosE 10.3.2 Release Notes
40
Known Problems and Limitations
When you attach certain hierarchical policies to subinterfaces as input policies,
secondary input policies, and output policies, incoming traffic loss can occur
when the number of subinterfaces to which the policies are attached exceeds
4600. [Defect ID 86741]
Ethernet statistics are incorrectly displayed for virtual port 8 of the ES2-S1 GE-8
IOA when that module is paired with the ES2 10G LM or the ES2 10G Uplink
LM. [Defect ID 174784]
The ES2 10G LM does not support framed routes configured for dynamic
subscriber interfaces. [Defect ID 83154]
A memory leak of about two percent can occur on the ES2 10G LM and result in
a module reset when a large number of successive SRP switchovers take place
with active DHCP clients. [Defect ID 86245]
On the ES2 10G LM, a VLAN ID of 0 assigned to an interface can prevent
packets from being properly forwarded. [Defect ID 176125]
ICR
When you configure ICR settings using a CLI macro, ICR commands are run in
quick succession. Sometimes, in such a scenario, the active SRP module resets
if the event that causes the change of state of the VRRP instance reaches the
ICR application before the ICR partition has been created. [Defect ID 184095]
Work-around
: To avoid this problem, add an additional delay of one second
using the
sleep
command in the macro, before the
ip vrrp
vrid
enable
command that is written in the macro to enable VRRP instance.
For example, consider a macro that contains the following commands:
ip vrrp
vrid
enable
ip vrrp
vrid
icr-partition
partitionId
Modify the macro, as follows, to add a delay of one second before the VRRP
instance ID is enabled on the router and a delay of another second before the
ICR partition that corresponds to the VRRP instance is created:
sleep 1
ip vrrp
vrid
enable
sleep 1
ip vrrp
vrid
icr-partition
partitionId
Содержание JUNOSe 10.3.2
Страница 8: ...viii Table of Contents JunosE 10 3 2 Release Notes ...
Страница 76: ...JunosE 10 3 2 Release Notes 68 Errata ...