Commissioning of the JUNG Smart Control IP
Date 2013-07-07 v1.1.3
30
2.6.3 Functions of the DCM page
Figure 2-29: Functions of the DCM page
Three functions can be used via the Door communication page.
The Door/Camera button can be used to set up a connection to a
door station, without the ring push-button of a door station having
been pressed, in order to display the current camera image or to
speak with a person at the door. If the camera image is displayed,
then images can also be saved manually.
The "Image memory" button can be used to check images taken
manually or automatically. If the snapshot function is active, and no-
one accepts the call, then the taken image is saved and marked as a
"new image" in the image memory. In addition, the red LED on the
front side of the Smart Control IP flashes.
It is possible to deactivate the ring tone using the "Call switch-off"
button. In this case, the red LED of the Smart Control IP is
illuminated continuously. The automatic display of the Door
communication page remains active when a ring push-button is
pressed.
2.7
Timer switch
The Smart Control IP possesses a weekly timer with up to eight
channels and up to eight times.
The switching commands are then transmitted as UDP commands
and can be evaluated, for example by a Facility Pilot Server.
For this, the types of the switching channels and the commands to be
transmitted must be matched.