![Jung Smart Control IP Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/jung/smart-control-ip/smart-control-ip_commissioning_2031685027.webp)
Commissioning of the JUNG Smart Control IP
Date 2013-07-07 v1.1.3
27
Figure 2-25: Setting of the microphone sensitivity
In the case of speech transmission, the volume and the microphone
sensitivity on the Smart Control IP must be matched to the values of
the door communication system. For this, the following values can
serve as a basis:
In the Smart Control IP
Microphone sensitivity:
Medium
In the priority controller of the SIP gateway:
Toggle threshold for "Counterpart speaking" [%]
50
Toggle length for "Counterpart speaking" [* 10 ms]
20
Counterpart speaking: microphone level [%]
0
Counterpart speaking: loudspeaker level [%]
30
Counterpart listening: microphone level [%]
30
Counterpart listening: loudspeaker level [%]
0