Commissioning of the JUNG Smart Control IP 

 

Date 2013-07-07 v1.1.3 

1.1 

Smart Control IP 

The Smart Control IP makes up to seven different main screen pages 
available:  

  Function  page:  In  the  basic  setting,  this  page  serves  as  the 

starting  page.  From  here,  the  buttons  can  be  used  to  switch 
directly  to  the  other  pages.  After  a  settable  time,  the  system 
jumps back to the starting page automatically. 

  Building  technology  1:  This  page  starts  an  instance  of  the 

integrated  web  browser. This page  can be used, for  example,  to 
display an HTML page of the FAP server, in order to visualise and 
control statuses of a KNX installation. 

  Building  technology  2:  This  page  starts  a  further  instance  of  the 

integrated  web  browser.  Additional  building  technology  functions 
can be visualised and controlled using this page. 

  Weather page: This page starts an instance of the integrated web 

browser,  using  which,  for  example,  the  current  weather  situation 
and the forecast for the coming days can be displayed. 

  Door communication: Together with a JUNG door communication 

system, this page allows transmission of images and sounds with 
up  to  eight  door  intercoms.  In  addition,  images  of  the  door 
cameras  can  be  stored  automatically  or  manually  in  an  image 
memory. 

  Timer:  This  page  is  used  to  set  the  times  and  the  values  to  be 

sent for up to eight channels. The commands of the timer are sent 
via UDP and evaluated, for example, by the Facility Pilot Server, 
in order to execute building technology functions. 

  Settings:  This  page  allows  local  access  to  the  integrated  web 

server,  in  order  to  adjust  network  connection  and  door 
communication functions. 

  Screen  cleaning:  This  page  locks  the  evaluation  of  the  touch-

sensitive screen and the three buttons for 30 seconds, in order to 
avoid  incorrect  operations  whilst  the  device  surface  is  being 
cleaned. 

 
It is possible to switch between the five first pages using the "Scroll" 
button.  The Timer,  Settings  and Screen  cleaning  pages  are opened 
directly from the function page. 
 
The  "Master  button"  does  not  open  a  particular  screen  page,  but 
sends  specified  commands  via  UDP.  These  commands  are 
evaluated,  for  example,  by  the  Facility  Pilot  Server,  in  order  to 
execute building technology functions. 

1.2 

Commissioning PC / Web Browser 

The  major  part  of  the  configuration  of  the  Smart  Control  IP  takes 
place using a PC, which accesses the configuration server integrated 
into the Smart Control IP via  a web browser (for example Firefox or 
Safari).  
 

Содержание Smart Control IP

Страница 1: ...Commissioning of the JUNG Smart Control IP Date 2013 07 07 v1 1 3 1 JUNG Smart Control IP...

Страница 2: ...web interface 10 2 3 3 General 11 2 3 3 1 Network 11 2 3 3 2 Date and time 12 2 3 3 3 Language 13 2 3 3 4 Design 14 2 3 3 5 System device password 15 2 3 3 6 Import and Export 16 2 3 4 Device 17 2 3 4...

Страница 3: ...ith an intuitive screen surface Thanks to the network connection configuration takes place simply and intuitively on the computer or laptop All the settings are made easily and the individual systems...

Страница 4: ...or intercoms In addition images of the door cameras can be stored automatically or manually in an image memory Timer This page is used to set the times and the values to be sent for up to eight channe...

Страница 5: ...ontrol IP Optionally a username and a password can also be saved 1 4 DCM connection To connect the Smart Control IP to a JUNG door communication system the image and sound information of the JUNG DCM...

Страница 6: ...ontrol IP the network settings of the two devices must be matched 2 1 Default settings The Smart Control IP has the following default settings Network settings Manual IP address 192 168 0 10 Gateway 1...

Страница 7: ...he device password then you can contact JUNG Customer Services to obtain a single validity password using the displayed TAN To adjust the network settings locally open the Network page using the Netwo...

Страница 8: ...gling the network settings In the manual network setting the IP address the gateway address the subnet mask and the DNS server can be adjusted Figure 2 5 Selecting the IP address Pressing the appropri...

Страница 9: ...via access to the integrated configuration web server 2 3 1 Login If the network address of the Smart Control IP was not changed locally the configuration web server is opened via the IP address 192 1...

Страница 10: ...the web interface Show Help If this option is highlighted then additional information is displayed for the currently highlighted input box In the left hand area it is possible to select the section w...

Страница 11: ...ed in the address line in order to set up the connection again and to continue with the configuration process If incorrect data is entered during manual address assignment various malfunctions may occ...

Страница 12: ...message is displayed and an attempt is made to restore the network connection If the fault persists the device performs a restart in order to reinitialise the network interface 2 3 3 2 Date and time...

Страница 13: ...the current hour MM the current minute SS the current second n is the character for the end of the text 2 3 3 3 Language Figure 2 11 Setting the language The operating interface of the Smart Control I...

Страница 14: ...g interface uses the light design with dark letters A dark design with white letters can also be set This setting affects all the pages set in the Smart Control IP Function page Settings Door communic...

Страница 15: ...e 2 13 Changing the password The Settings page of the Smart Control IP and the web configuration are each protected with a password To change these passwords the old password must be entered and then...

Страница 16: ...sci is created which can then be saved to the PC using the file download of the web browser A saved configuration can be written back into a Smart Control IP using the Import function The Overwrite n...

Страница 17: ...t Control IP Date 2013 07 07 v1 1 3 17 2 3 4 Device 2 3 4 1 Operation LED Figure 2 15 Setting the operation LED The Smart Control IP has a blue operation LED which can either be permanently switched o...

Страница 18: ...communication call After a settable time the display is then switched off automatically If for example during the evening it is relatively dark in the area of the Smart Control IP then full display br...

Страница 19: ...ple the Smart Control IP is primarily used for local operation of a room using the Facility Pilot Server it may be wise to use this Building Technology page as the start page Here the different pages...

Страница 20: ...button is pressed the Smart Control IP can transmit specified commands A line break hexadecimal 0x0A is inserted automatically as a character for the end of the commands for Press and or Release For e...

Страница 21: ...rt Control IP may deviate from the value of a comparable measurement device The structure of the wall upon which the Smart Control IP is installed and the air currents through free convection of room...

Страница 22: ...egrated web browser which then for example displays the data from one Facility Pilot Server each The correct URL e g http 192 168 1 202 8080 is required for the web page to be displayed If this page c...

Страница 23: ...2 21 Weather page setting When the Weather page is opened the Smart Control IP starts an instance of the integrated web browser A web page matched to the display size and the design of the Smart Cont...

Страница 24: ...structure and scope of functions of the door communication system Of key importance here are for example the use of door stations with or without video function and the number of door stations Within...

Страница 25: ...n be a fixed IP address or the name defined by a name server The value used as realm by the SIP server is entered in the field SIP domain Typical default values are fritz box when using a FRITZ Box 3C...

Страница 26: ...y use internal call number without leading special characters The video URL is made up of the address of the video streamer and the port number here 12000 which is set in the video streamer Enter the...

Страница 27: ...ues of the door communication system For this the following values can serve as a basis In the Smart Control IP Microphone sensitivity Medium In the priority controller of the SIP gateway Toggle thres...

Страница 28: ...using the Speak button Pressing the Speak button again terminates the speech connection When the door is opened by pressing the Door opener button the speech connection is also terminated The image fr...

Страница 29: ...there is a Micro SD memory card in the side slot of the Smart Control IP then individual images of the door camera can be saved With the snapshot function activated an image is taken automatically wh...

Страница 30: ...snapshot function is active and no one accepts the call then the taken image is saved and marked as a new image in the image memory In addition the red LED on the front side of the Smart Control IP fl...

Страница 31: ...channel The name is used for display purposes in the Smart Control IP The following values are available for selection Binary Analogue 0 100 Analogue 0 255 Analogue 0 65535 When making settings on th...

Страница 32: ...ro lighting setting Sunrise switching times 00 00 11 59 if sunrise occurs before the set time for example in the summer months then at sunrise the switching time command e g external lighting OFF is t...

Страница 33: ...ation of the building latitude and longitude the time zone and the automatic summer time determination must be entered in the web interface to calculate the sunrise and sunset times Entry of the descr...

Отзывы: