Operating Manual: FRWM200 – Smoke Alarm Device with Radio Link
EN
65
10.1 Cancelling a device from a
radio group
You must cancel a device from a radio group in
the following cases:
•
Remove device from an existing radio
group and connect it to another group
•
Remove the defective device
from the radio group
In the radio group from which the device was
removed, you must set all the devices to factory
settings and re-connect them:
f
Observe chapter 6.1 „Setting up radio
f
Observe chapter 7 „Expanding radio group
and learning mode“ on page 62.
f
Observe chapter 6.2 „Completing radio
Alarm forwarding takes place in two directions,
with the following forwarding times:
•
Alarm forwarding within a
radio group or a shared radio
group = approx. 20 seconds
•
Alarm forwarding from a radio group to
shared radio group = approx. 60 seconds
There is no alarm forwarding from the shared
radio group to the individual radio groups.
Repeater function
Repeater function
Through the repeater function, radio signals are
forwarded from one signalling device through
available devices to unreachable devices.
If you need specific, complex and,
where applicable, cascading connecti-
on functions for the alarm forwarding,
please contact the manufacturer (see
chapter 15 „Accessories, spare parts
11 Alarm forwarding
and alarm stop