Operating Manual: FRWM200 – Smoke Alarm Device with Radio Link
EN
51
The use of smoke alarm devices is governed
by DIN 14676.
Minimum equipment
Minimum equipment
•
Bedrooms
•
Children’s bedroom
•
Guest room
•
Hallways and all other rooms
which serve as an escape route
•
Stairwells of family houses
Optimal equipment
Optimal equipment
•
All living and hobby rooms (except in
Berlin and Brandenburg – here such
equipment is also required by law)
•
Heating and work spaces
•
Office or workroom
•
Cellar
•
Attic
Conditional equipment
Conditional equipment
•
In kitchens, smoke alarm devices must
only be installed when false alarms
(e.g., caused by steam) are excluded
Not recommended
Not recommended
•
Bathrooms are excluded from the
installation of smoke alarm devices
due to the high development of steam
Kitchen
Livingroom
4.1 Area to be monitored
Use a device if at least one of the following
applies:
•
Monitoring area less than 60 m
2
,
and ceiling height of less than 6 m
•
Ceiling panels (height lower
than 20 cm) with joists (ceiling
surface less than 36 m
2
)
Use additional equipment if at least one of the
following applies:
•
Monitoring area greater than 60 m
2
•
Ceiling height greater than 6 m
•
High partial walls
•
Separating pieces of furniture
•
Platform / gallery (area greater than
16 m², at least 2 m long and wide)