– 54 –
No.
Description of error detected
Cause of occurrence expected
Items to be checked
−
Meda cover open
•
Cover of the slot of media is open.
•
Close the cover.
E000 Execution of data initialization
(Ths s not the error.)
• When the machine head is changed.
• When the initialization operation is ex
-
ecuted
E003 Disconnection of synchro
-
nzer connector
• When position detection signal is not input
from the sewng machne head synchro-
nzer.
• When the synchronizer has broken.
• Belt s loose.
• Machne head s not proper.
• Motor pulley s not proper.
• Check the synchronizer connector (CN33) for
loose connecton and dsconnecton.
• Check whether the synchronizer cord has
broken snce the cord s caught n the ma-
chne head.
• Check the belt tension.
• Check the setting of the machine head.
• Check the setting of the motor pulley.
E004
Synchronzer lower poston
sensor falure
E005
Synchronzer upper poston
sensor falure
E007
Overload of motor
• When the machine head is locked.
•
When sewing extra-heavy material beyond
the guarantee of the machne head.
• When the motor does not run.
• Motor or drver s broken.
• Check whether the thread has been entangled
n the motor pulley.
• Check the motor output connector (4P) for
loose connecton and dsconnecton.
• Check whether there is any holdup when
turnng the motor by hand.
E008 Undefined machine head is
selected
• The machne head that does not support
the SC-922 is selected.
• Check the machine head selection using
functon settng No. 95.
E011(*)
Meda s not nserted.
• Meda s not nserted.
• Turn the power OFF and check the meda.
E012(*)
Read error
• Data of media cannot be read.
• Turn the power OFF and check the meda.
E013(*) Write error
• Data of media cannot be written.
• Turn the power OFF and check the meda.
E014(*) Write protect
• Meda s n the state of wrtng prohbton.
• Turn the power OFF and check the meda.
E015(*)
Format error
• Formattng cannot be performed.
• Turn the power OFF and check the meda.
E016(*) External media capacity over • Capacity of media is short.
• Turn the power OFF and check the meda.
E019(*)
Fle sze over
• Fle s too large.
• Turn the power OFF and check the meda.
E032(*)
Fle nterchangeablty error
• There is no interchangeability of file.
• Turn the power OFF and check the meda.
E041(*)
Sewng recorder error
• Ths error number s dsplayed n the event
of a sewng recorder data fault.
• Reset swtch
E044(*) Date and time error
• Ths error number s dsplayed n the event of
operaton/data fault concernng date or tme of
day.
• Reset swtch
I
n addton, there are the followng error codes n ths devce. These error codes nterlock (or lmt functon) and nform
the problem so that the problem is not enlarged when any problem is discovered. When you request our service, please
confirm the error codes.
Error code list
[Checking procedure of the error code]
1) Turn ON the power swtch wth
swtch
3
held pressed.
2) The latest error number s dsplayed
on ndcator
B
wth a blp.
3) Contents of previous errors can be
checked by pressng
swtch
3
or
swtch
4
.
(When the confirmation of the con
-
tents of prevous error advanced to
the last, the warnng sound peeps n
sngle tone two tmes.)
(Caution) When
switch
3
is pressed, the previous error code of the currently displayed one is
displayed. When
switch
4
is pressed, the next error code of the currently displayed
one is displayed.
6
5
4
3
1
B
A
2
7
* the error number attached with an asterisk (*) is displayed only in the case a fault occurs when the It
panel is connected to the sewing machine.