– 56 –
E703(*)
Operaton panel s connected
to the unexpected sewing
machine. (Error of sewing
machne model)
• The operaton panel and the sewng
machne model do not match n the ntal
communcaton.
•
Connect the operation panel to the correct
model of the sewng machne.
E704(*)
System verson msmatch
• The system verson s dfferent from the
correct one n the ntal communcaton.
• Re-wrte the system verson to the one that
can be used wth the operaton panel.
E730 Encoder failure
• When the motor signal is not properly input
-
ted.
• Check the motor signal connector (CN30) for
loose connecton and dsconnecton.
• Check whether the motor signal cord has
broken snce the cord s caught n the machne
head.
• Check whether the inserting direction of the
motor encoder connector s wrong.
E731
Motor hole sensor falure
E733
Inverse rotaton of motor
• Ths error occurs when the motor s run-
nng at 500 st/mn or more n the opposte
drecton of that of rotaton ndcaton durng
motor s runnng.
• Check whether the machine head corresponds
wth the machne type settng.
• Check whether the main-shaft motor encoder
wre s connected ncorrectly.
• Check whether the main-shaft motor wire for
power supply s connected ncorrectly.
E799
Thread trmmng operaton
tme-ou
• The thread trmmng control operaton s not
completed wthn the predetermned tme
(wthn three seconds).
• Check whether the machine head actually
nstalled s dfferent from the machne head
selecton.
• Check whether the motor-pulley diameter
does not match ts settng (effectve dam-
eter).
• Check whether the belt has slackened.
E808
Solenod short crcut
• Solenod power does not become normal
voltage.
• Check whether the machine head cord is
caught n the pulley cover or the lke.
E809
Holdng moton falure
• Solenod s not changed over to holdng
moton.
• Check whether the solenoid is abnormally
heated. (CTL circuit board asm. Circuit is
broken.
E810
Solenod current abnormalty • Solenod rare short-crcut.
• Solenod resstance
E811
Abnormal voltage
• When voltage higher than guaranteed one
s nputted.
• 200V has been inputted to SC-922 of 100V
specifications.
• JA : 220V is applied to 120V box.
• CE : 400V is applied to 230V box.
• Check whether the applied power voltage is
higher than the rated v (plus) 10% or
more.
• Check whether 100V/200V changeover con
-
nector s mproperly set.
In the aforementioned cases, POWER p.c.b
s broken.
• When voltage lower than guaranteed one is
nputted.
• 100V has been inputted to SC-922 of 200V
specifications.
• JA : 120V is applied to 220V box
• Inner crcut s broken by the appled over-
voltage
• Check whether the voltage is lower than the
rated voltage - (mnus) 10% or less.
• Check whether 100V/200V changeover con
-
nector s mproperly set.
• Check whether fuse or regenerative resis
-
tance s broken.
E906
Operaton panel transmsson
falure
• Disconnection of operation panel cord
• Operaton panel has broken.
• Check the operation panel connector (CN38)
for loose connecton and dsconnecton.
• Check whether the operation panel cord has
broken snce the cord s caught n the machne
head.
E924
Motor drver falure
• Motor drver has broken.
E942 Faulty EEPROM
• Data cannot be written on the EEPROM.
• Turn the power OFF.
* the error number attached with an asterisk (*) is displayed only in the case a fault occurs when the It
panel is connected to the sewing machine.
No.
Description of error detected
Cause of occurrence expected
Items to be checked
Содержание SC-922