background image

www.rm-suttner.com

page 1, Ver. 01.2021

The injector ST-160.2 is used for admixing liquid detergents to the volume flow in the high- 

and low-pressure range using the Venturi principle. The injector housing and the mounted 

parts are made of stainless steel. 

The injector includes a pair of nozzles. It features a connection for an air valve. For being 

able to foam the admixed detergents, foam lances with and without air injector can be 

used. For a good foaming result, the correct injector nozzles and inserts must be selected.

The injector is designed for suction of detergents and disinfectants. For details, please refer 

to Directive 67/548/EEC.

The injector must only be used with fluids of Group I (e.g. water).

All safety instructions and regulations for high-pressure cleaners such as DIN EN 60335-

79-2 and DIN EN 1829-1 are to be complied with.

The operator must only use the injector if it is in a proper technical condition, without any 

structural alterations, as intended, being aware of safety and hazards, and complying with 

this User Manual. Only adults familiar with the use of high-pressure cleaners are authorised 

to use the injector.

The injector must not be operated using abrasive materials. In order to avoid damage to 

the injector, install a fine filter with a recommended mesh size of 50 μm in the water supply 

to the high-pressure cleaner. Install a suitable suction filter in the chemical agent hose.

Also comply with the operating instructions of the devices and accessories connected to 

the injector and the regulations applying to the detergents.

1  Inlet

2  Outlet

3  Compressed air connection

4  Housing dosing valve (rotating)

5  Chemical agent connection

6 Dosing scale

7 Adjusting wheel

    Flow direction

User Manual easy 

ST-160.2 foam and disinfectant unit. Product No.: 200 160 635

Description

Intended Use

Hazard! If these instruc

-

tions are not complied with, 

there is a risk of life and 

limb and property damage!

The injector is designed for permanent use at a tempe

-

rature of up to about 60 °C. In any case, the user has 

to wear suitable protective equipment such as safety 

gloves, shoes, and goggles. In general, the applicable 

local safety regulations are to be complied with.

An aerosol may be formed by the foam and disinfectant. 

In order to avoid inhalation, wear a suitable respiratory 

protection! 

Ensure sufficient ventilation!

IG: Female thread / AG: Male thread / G: Withworth pipe thread acc. 

to DIN ISO 228, ident. BSP = British Standard Pipe / NPT: National 

Pipe Thread (American Thread standard) / Kg: kilogram

Read this User Manual 

thoroughly before using the 

unit! Keep the User Manual 

in a safe place for later re

-

ference or the subsequent 

owner!

This User Manual was 

established using utmost 

care. However, we do 

not accept any liability for 

possible mistakes in this 

User Manual and their 

consequences.

Safety

Risk of burns and scalds by hot media!

Formation of aerosol!

Specifications

Maximum allowable pressure

350.0 bar / 35.00 MPa

Maximum volume flow

60.0 l/min

Water temperature, permanent

60 °C

Water temperature, temporary

max. 90 °C

Ambient temperature

up to 60 °C

Nozzle size

1.6 / 2.0

Connection inlet

G 1/2 F

Connection outlet

G 1/2 F

Connection compressed air

M14

Connection chemical agent

Ø 9 mm

Weight

1,207 g

Dimensions (W / H / D)

128 x 80 x 163 (with support)

Maximum size of solids

50 μm

Отзывы: