– 52 –
External input/output connector
which can take
out the following signals that are convenient when
installing counter or the like outside is prepared.
(Caution) When using the signals, consult engi-
neers who have electrical knowledge.
9. EXTERNAL INPUT / OUTPUT CONNECTOR
Table of assignment of connector and signal
JUKI genuine part No.
Connector : Part No. HK016510130
Pin contact : Part No. HK016540000
CN42
Signal name
Description
Electric spec.
1
+5V
—
Power source
2
LS (N)
Output
Rotation signal 360 pulses/rotation
DC5V
3
N. C.
—
—
4
UDET (N)
Output
“L” is output when needle bar is at LOW position.
DC5V
5
DDET (N)
Output
“L” is output when needle bar is at UP position.
DC5V
6
HS (N)
Output
Rotation signal 45 pulses/rotation
DC5V
7
BTD (N)
Output
“L” is output when the back-tack solenoid works.
DC5V
6
TRMD (N)
Output
“L” is output when the thread trimmer solenoid works.
DC5V
9
LSWO (P)
Output
Rotation request (pedal or the like) monitor signal
DC5V
10
S. STATE (N)
Output
“L” is output when the sewing machine is in the stop state.
DC5V
11
LSWINH (N)
Input
Rotation by pedal is prohibited while “L” signal is being inputted.
DC5V, -5mA
12
SOFT
Input
Rotation speed is limited to the soft-speed while “L” signal is being inputted.
DC5V, -5mA
13
SGND
—
0V
Input/
output