– 45 –
.....
Re-sewing function (Function setting No. 109)
When the IP-100 is connected, this function is used to stop/use the re-sewing function (sewing retried in the
middle of operation).
0: off Re-sewing function disabled
1: on Re-sewing function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
/////
Unilateral needle selection function (Free stitching/ Overlapped stitching) (Function setting No. 110)
When a reverse or overlapped stitching pattern is selected, this function is used to stop/use the unilateral needle
selection function. When 0 (disable) is selected, unilateral needle selection is disabled for the reverse or over-
lapped stitching pattern.
0: off Unilateral needle selection function (during free stitching) disabled
1: on Unilateral needle selection function (during free stitching) enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
¡¡¡¡¡
Unilateral needle selection function (Corner Pattern) (Function setting No. 111)
When the IP-100 is connected and a corner pattern is selected in this condition, this function is used to stop/use
the unilateral needle selection function. When 0 (disable) is selected, arbitrary unilateral needle selection is
disabled for the corner pattern.
0: off Unilateral needle selection function (during corner pattern) disabled
1: on Unilateral needle selection function (during corner pattern) enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
™™™™™
Selection of teaching operation (Function setting No. 112)
When the teaching switch is pressed, the resultant operation is selected.
0: Normal (Teaching operation is performed under the conditions of Te Unilateral
Needle Selection.)
1: Teaching operation only by unilateral needle selection (It is unnecessary to press the
teaching switch in order to start up the teaching operation.)
2: Teaching operation disabled in the bilateral needle selection (Press the teaching switch
after the unilateral needle state has been assumed.)
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
1
0
9
1
1
1
0
1
1
1
1
1
1
1
2
0