![JUKI SC-910 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/juki/sc-910/sc-910_engineers-manual_2029522026.webp)
– 22 –
E810
Solenoid short-circuit
When the short-circuited solenoid is desired to be driven.
Check whether the solenoid is short-circuited.
E811
Overvoltage
1. When voltage upper than guaranteed one is
1. Check whether the applied power voltage is higher than the rated v (plus)
inputted.
10% or more.
2. When 200V is inputted for 100V setting.
2. Check whether 100V/200V changeover connector is set by mistake.
In the above cases, POWER circuit board has broken.
E813
Low voltage
1. When voltage lower than guaranteed one is
1. Check whether the votage is lower than the rated voltagw - (minus) 10% or less.
inputted.
2. Check whether 100V/200V changeover connector is set by mistake.
2. When 100V is inputted for 200V setting.
E920
GA failure
Abnormality of gate array
When return is not performed even after turning OFF the power, the possibility of gate
array breakage is large.
E922
Main shaft motor control is impossible.
When main shaft motor cannot be controlled.
Turn OFF the power.
E924
Motor driver failure
Motor driver has broken.
Turn OFF the power.
E940
Bird's nest sequence error
Bird's nest prevention sequence is not completed.
Turn OFF the power.
E941
GA failure
Abnormality of gate array
When return is not performed even after turning OFF the power, the possibility of gate
array breakage is large.
E942
EEPROM failure
Writing is not completed even after the lapse of 10
Turn OFF the power.
[ms] or more.
E944
Left needle is uncontrollable.
In case of LH sewing machine with organized split
Check whether needle control connectors (CN55 and CN56) are loosened or discon
needle bar mechanism
nected.
1. Same error is not detected yet.
2. Home position signal is ON when left needle is
locked.
3. Home position signal is OFF when left needle is
released.
E945
Right needle is uncontrollable.
In case of LH sewing machine with organized split
Check whether needle control connectors (CN55 and CN56) are loosened or discon
needle bar mechanism
nected.
1. Same error is not detected yet.
2. Home position signal is ON when right needle is
locked.
3. Home position signal is OFF when right needle is
released.
No.
Description of error detected
Cause
Item to be checked or corrective measure