– 32 –
No.
Item
Description
Setting range
106
Presser lifter
When the IP-100 is connected and a corner pattern is selected, this function
0/1
44
switch 1 needle
provides the capability of stitch compensation during in-corner sewing the
compensation
the aid of a presser lifter switch.
function
0: OFF Compensation sewing disabled with the presser lifter switch
1: ON Compensation sewing enabled with the presser lifter switch
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine
head.
* When using this function, it is necessary to set up the presser lifter function
selection (No.117) at 0 (function disabled).
107
In-corner sewing
When the IP-100 is connected and a corner pattern is selected, this function
0/1
44
one-shot function
is used to perform automatic one-shot sewing for in-corner sewing.
0: OFF Automatic one-shot sewing disabled during in-corner sewing
1: ON Automatic one-shot sewing enabled during in-corner sewing
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine
head.
108
In-corner presser
When the IP-100 is connected and a corner pattern is selected, this function
0/1
44
lifter function
is used to perform automatic presser rising after the completion of in-corner
sewing.
0: OFF Automatic presser rising disabled after the completion of in-corner sewing
1: ON Automatic presser rising enabled after the completion of in-corner sewing
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
* This function is available only if the automatic presser lifter unit (AK) is connected.
109
Re-sewing
When the IP-100 is connected, this function is used to stop/start sewing again
0/1
45
function
(sewing retried in the middle of operation).
0: OFF Re-sewing function disabled
1: ON Re-sewing function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
110
Unilateral needle
When a reverse or overlapped stitching pattern is selected, this function is
0/1
45
selection function used to stop/start the unilateral needle selection. When 0 (disable) is selected,
(Free stitching/
unilateral needle selection is disabled for the reverse or overlapped stitching
overlapped
pattern.
stitching)
0: OFF Unilateral needle selection function (during free stitching) disabled
1: ON Unilateral needle selection function (during free stitching) enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
111
Unilateral needle
When the IP-100 is connected and a corner pattern is selected, this function is
0/1
45
selection function used to stop/start the unilateral needle selection. When 0 (disable) is selected,
(Corner pattern)
arbitrary unilateral needle selection is disabled for the corner pattern.
0: OFF Unilateral needle selection function (during corner pattern) disabled
1: ON Unilateral needle selection function (during corner pattern) enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
112
Selection of
Selection of operation available when the teaching switch is pressed.
0 to 2
45
teaching
0: Normal (Teaching operation is performed under the conditions of teaching
operation
+ unilateral needle selection.)
1: Teaching operation only by unilateral needle selection (It is unnecessary
to press the teaching switch in order to start up the teaching operation.)
2: Teaching operation disabled in the bilateral needle selection (Press the
teaching switch after the unilateral needle state has been assumed.)
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
113
Number of
Selection of the number of reproduced stitches when corner teaching
0/1
46
stitches for
(measuring the number of stitches for unilateral needle sewing) is carried out.
teaching replay
0: The number of replay stitches coincides with that of measured stitches.
1: The number of replay stitches is less by 1 than that of measured stitches.
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
114
Left bobbin
When the IP-100 is connected, this function is used to stop/start the left
0/1
46
thread counter
bobbin thread counter.
function
0: OFF Left bobbin thread counter function disabled
1: ON Left bobbin thread counter function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
115
Right bobbin
When the IP-100 is connected, this function is used to stop/start the right
0/1
46
thread counter
bobbin thread counter.
function
0: OFF Right bobbin thread counter function disabled
1: ON Right bobbin thread counter function enabled
* Setting is possible only if LH-4168 or LH-4188 is selected for the machine head.
1
0
7
0
1
0
8
1
1
0
9
1
1
1
0
1
1
1
1
1
1
1
2
0
1
1
3
0
1
1
4
1
1
1
5
1
Indication of
Ref.
function setting
page
1
0
6
1