– 1 –
1. SPECIFICATIONS
Supply voltage
Single phase 100 to 120V
3-phase 200 to 240V
Single phase 200 to 240V
Frequency
50 Hz / 60 Hz
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating temperature range
Temperature : 0 to 40
°
C
Temperature : 0 to 40
°
C
Temperature : 0 to 40
°
C
Operating humidity range
Humidity : 90% or less
Humidity : 90% or less
Humidity : 90% or less
Power consumption
650VA
650VA
650VA
2. OUTLINE
(1) Features
1) Voltage changeover function of single phase 100 to 120V/3-phase 200 to 240V is provided.
The control box with voltage changeover function can be used either for single phase 100 to 120V or for 3-
phase 200 to 240V by replacing the power cord up to the power switch and changing the voltage changeover
connector inside the box.
In addition, it can be used for single phase 200 to 240V.
2) By using IP-100, the sewing management information such as output display, etc. can be displayed.
3) The conventional JUKI optional devices can be used without any adjustment.
However, when AE (bobbin thread remaining amount detection device) is used, it is necessary to separately
purchase the optional circuit board.
4) By using the flash ROM for CPU, the future version-up can be adapted.
5) SC-910 control box can be used for DD (direct-drive) system machine head and drive system machine head
by connecting the small-sized motor unit (M-91).