– 25 –
Specified No.
Specified value
(2) Setting for functions
Functions can be selected and specified by means of the four setting switches and light emitting diode located
inside the front cover of the SC-910/SC-910A.
(Caution) • Do not perform switch operations other than those described in the following explanations.
• Be sure to re-turn the power switch ON after one second or more has passed. If the power is
turned ON immediately after turning it OFF, the sewing machine may not work normally. In
this case, turn ON the power again.
WARNING :
To avoid possible personal injuries caused by movement other than that you desired, do not operate the switches in the
procedure other than those required, as described below, to specify the functions.
How to change over to the function setting modo
1) Turn OFF the power to the unit.
2) Open the front cover.
3) Pressing switch
, turn ON the power to the unit.
4) Indication
will be shown on the display. (If the
indication fails to change, re-perform the proce-
dures 1) to 3).
Switch for entering specified value changed and
updating setting No. in UP direction
Switch for entering specified value changed and
updating setting No. in DOWN direction
Up switch (UP)
Down switch (DOWN)