– 80 –
No.
Function
Setting range
Initial value
Remarks
K059
Moving limit range in -Y direction (front side)
-20 to 10 mm
-20
(1903 : -3)
In the state of shipment, no
work clamp foot configura
-
tion is considered.
K060 Jump feed speed of XY
(Setting possible in the unit of 10 pps)
100 to 4000
pps
2000
K061 XY feed forward / back speed
(Setting possible in the unit of 10 pps)
100 to 4000
pps
500
K062 When the power supply is turned on, automatic prepara-
tion is possible without pressing the READY key.
: Normal
: Automatic preparation is operated when the
power supply is ON.
-
K063 While the needle stays in an upper position, a current is
maintained in the main motor to make the needle hard to
down.
: Holding disabled
: Holding enabled
-
K066 Number of pulses for work clamp foot interlock
wiper operation
30 to 60
45
K068 At preparatory state, time to output thread ten-
sion can be set up at the time of thread tension
setting.
0 to 20
20
K091 Used to enable/disable the feed forward travel function,
when checking the shape, while the needle is in its lower
position.
: Disable
: Enable
-
K092 Used to enable/disable the feed forward travel function,
when checking the shape, by means of the pulley.
: Disable
: Enable
-
K093 Returning method selection of standby position of the
thread clamp
: Except for LK-1900BB and 1903BB
: LK-1900BB, 1903BB
(Refuge position of sewing end is moved to
standby position by the work clamp foot switch.)
-
LK-1900BB, 1903BB :
Refuge position of sewing
end
Standard model : Normal
When this function is set
up conventionally for LK-
1900BB and 1903BB, a
cycle time becomes long af-
ter suction of shorter thread
remaining thread trimmer
because the needle thread
clamp moves forward.
K096 ON delay time of shorter thread remaining thread trimmer
Time to shorter thread remaining thread trimmer ON from
thread waste suction nozzle / thread waste suction ON
0 to 1000 ms
100
Only LK-1900BB and 1903
BB are displayed.
K097 ON time of shorter thread remaining thread trimmer
Time to OFF from ON of shorter thread remaining thread
trimmer
0 to 1000 ms
200
Only LK-1900BB and 1903
BB are displayed.
K098 Work clamp foot lifter delay time of shorter thread remain-
ing thread trimmer
Time to the start of work clamp foot lifter from ON of short-
er thread remaining thread trimmer
0 to 1000 ms
100
Only LK-1900BB and 1903
BB are displayed.
Содержание LK-1900B series
Страница 128: ... 114 4 Parts to which grease is applied 1 Work clamp foot lifter area 2 Wiper area Grease JUKI Grease A Grease ...
Страница 129: ... 115 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A ...
Страница 130: ... 116 5 Feed area Grease Grease D ...
Страница 131: ... 117 6 Needle bar and main shaft area 7 Lower shaft area JUKI Grease A JUKI Grease A ...
Страница 132: ... 118 8 Needle thread clamp mechanism area For LK 1900BB 1903BB Grease ...
Страница 133: ... 119 9 LK 1901B relations Grease ...
Страница 134: ... 120 10 LK 1903B relations Grease ...
Страница 135: ... 121 11 LK 1900BB 1903BB relations JUKI Grease A ...
Страница 164: ... 150 4 Power supply circuit diagram Single phase SDC board MAIN board Light blue Orange Brown Yellow Red Black ...