– 145 –
WARNING :
When it is necessary to open the control box containing electrical parts, be sure to turn the power off and wait for five minutes or more before opening the cover in
order to prevent accident leading to electrical shock. If the work is performed while the power is ON, never touch other than necessary parts.
Trouble
Cause (1)
Cause (2)
Check and corrective measures
22.
Error E915 appears.
22-1) Communication between the
MAIN and panel cannot be
performed.
1-A) Connection defective
Check whether there is loose in CN34 of the MAIN board.
1-B) Control circuit is out of order.
Replace the operation panel or MAIN board.
23.
Error E918 appears.
23-1) Cooling of the MAIN board is
not possible.
1-A) Fan does not rotate.
Check the status of connections or the adhesion of dust at
CN33 (fan) of the MAIN board.
1-B) Heat dissipation of the element
is not possible.
Make sure that all setscrews of the main board are tightened.
24. When the sewing machine is
stopped, error E396 appears.
24-1) It does not become to the state
that the shorter thread remain-
ing thread trimming cylinder
turns ON and the sensor turns
OFF before origin retrieval or
during shorter thread remain-
ing thread trimming.
1-A) An air is not supplied.
Turn OFF the power switch and check an air pressure.
1-B) Cylinder sensor mounting posi-
tion is inadequate.
Make sure that the cylinder sensor LED lights up in the initial
state of power supply ON and LED goes out in the operating
position.
1-C) Cylinder malfunction
Make sure that the cylinder can be driven. If the cylinder can
not be driven, remove its cause.
Make sure that there is any loosening or missing of pins on
CN46 of MAIN board.
25. When the sewing machine is
stopped, error E397 appears.
25-1) It does not become to the state
that the suction nozzle cylinder
turns ON and the sensor turns
OFF during shorter thread
remaining thread trimming.
1-A) Cylinder sensor mounting posi-
tion is inadequate.
Make sure that the cylinder sensor LED lights up in the initial
state of power supply ON and LED goes out in the operating
position.
1-B) Cylinder malfunction
Make sure that the cylinder can be driven. If the cylinder can
not be driven, remove its cause.
Make sure that there is any loosening or missing of pins on
CN46 of MAIN board.
Содержание LK-1900B series
Страница 128: ... 114 4 Parts to which grease is applied 1 Work clamp foot lifter area 2 Wiper area Grease JUKI Grease A Grease ...
Страница 129: ... 115 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A ...
Страница 130: ... 116 5 Feed area Grease Grease D ...
Страница 131: ... 117 6 Needle bar and main shaft area 7 Lower shaft area JUKI Grease A JUKI Grease A ...
Страница 132: ... 118 8 Needle thread clamp mechanism area For LK 1900BB 1903BB Grease ...
Страница 133: ... 119 9 LK 1901B relations Grease ...
Страница 134: ... 120 10 LK 1903B relations Grease ...
Страница 135: ... 121 11 LK 1900BB 1903BB relations JUKI Grease A ...
Страница 164: ... 150 4 Power supply circuit diagram Single phase SDC board MAIN board Light blue Orange Brown Yellow Red Black ...