– 139 –
WARNING :
When it is necessary to open the control box containing electrical parts, be sure to turn the power off and wait for five minutes or more before opening the cover in
order to prevent accident leading to electrical shock. If the work is performed while the power is ON, never touch other than necessary parts.
Trouble
Cause (1)
Cause (2)
Check and corrective measures
1. No display at the operation
panel.
1-1) DC power is not supplied to
the operation panel.
1-A) AC power is not supplied.
Check whether if a power supply is available at the power
switch.
1-B) The FLT board (3-phase spec-
ification, CE specification) has
no power supply.
Check whether AC 200 to 240V is available between pins 4-5,
5-6 and 6-4 of CN1 in the FLT-T board or between pins 4-5 of
CN1 in the FLT-CE board.
1-C) The SDC board has no power
supply.
Check whether AC 200 to 240V is available between pins 1-2
of CN16 in the SDC board.
If no voltage is found, check the connections toward the FLT
board.
If there is no problem in connections, replace the FLT board.
1-D) The MAIN board has no power
supply.
Check whether 24V is available between pins 1-4 of CN38 in
the MAIN board and 1-4 of CN13 in the SDC board.
If no voltage is found, replace the SDC board.
1-E)
The operation panel has no
power supply.
Confirm that the cable from the operation panel is connected
to CN34 of the MAIN board.
If there is no problem in connections, replace the MAIN board
or the operation panel.
2.
When turning ON the power,
error E946 appears.
2-1) The model information written
to the INT board can not read.
Check the connection of CN30 of the MAIN board.
If there is no problem in connections, replace the MAIN board
or machine head INT board.
3.
When turning ON the power,
error E916 appears.
3-1) The communicate with the
SDC board can not be normal-
ly.
Check the connection of CN37 of the MAIN board and CN11 of
the SDC board.
If there is no problem in connections, replace the MAIN board
or SDC board.
4.
When turning ON the power,
error E731 appears.
4-1) The encoder signal of machine
head main motor can not read
normally.
Check the connection of CN15 of the SDC board.
If there is no problem in connections, replace the SDC board
or main motor.
(3) Electrical components
(Refer to "Block diagram".)
Содержание LK-1900B series
Страница 128: ... 114 4 Parts to which grease is applied 1 Work clamp foot lifter area 2 Wiper area Grease JUKI Grease A Grease ...
Страница 129: ... 115 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A ...
Страница 130: ... 116 5 Feed area Grease Grease D ...
Страница 131: ... 117 6 Needle bar and main shaft area 7 Lower shaft area JUKI Grease A JUKI Grease A ...
Страница 132: ... 118 8 Needle thread clamp mechanism area For LK 1900BB 1903BB Grease ...
Страница 133: ... 119 9 LK 1901B relations Grease ...
Страница 134: ... 120 10 LK 1903B relations Grease ...
Страница 135: ... 121 11 LK 1900BB 1903BB relations JUKI Grease A ...
Страница 164: ... 150 4 Power supply circuit diagram Single phase SDC board MAIN board Light blue Orange Brown Yellow Red Black ...