– 6 –
(2) Names and explanation of switches on the operation panel
2-1 Standard Application
❶
❷
❺
❹
❸
❻
❼
❽
❾
No.
NAME
FUNCTION
❶
LCD display
Various data such as pattern
No., shape, etc. are displayed.
❷
READY key
Press this key when starting
sewing.
Every time this key is pressed,
change-over of sewing ready
set state and data set state can
be performed.
❸
RESET key
Press this key when releasing
error, traveling the feed mech-
anism to its initial position,
counter resetting, etc.
❹
MODE key
This key is used for displaying
the mode screen.
❺
PRESSER and
WINDER key
This key lifts or lowers the
presser. When the presser goes
up, the needle bar travels to the
origin and when it comes down,
the needle bar travels to the
right.
This key is pressed when per-
forming bobbin winding.
❻
ITEM SELECT key This key is used to select the
data No. and other kinds of
data.
❼
DATA CHANGE key This key is used to change the
pattern No. and other kinds of
data.
This key is used to move the
feed forward on a stitch-by-
stitch basis.
No.
NAME
FUNCTION
❽
EDIT key
This key is used to display the
edit screen, to select the item or
to display the detail screen.
❾
RETURN key
This key is used to return the
screen to the previous one.
DIRECT PATTERN This key registers the pattern.
When this key is pressed, the
pattern registered here can sew
immediately.
X/Y scale, sewing position, etc.
can be changed and registered.
THREAD TENSION
key
The thread tension screen is
displayed.
THREAD CLAMP
key
This key selects enable/disable
of needle thread clamp. When it
is enabled, needle thread clamp
display LED lights up.
(Cau-
tion) 1.
THREAD CLAMP
LED
When this LED lights up, needle
thread clamp operates.
SET READY LED
The LED lights up under the
sewing mode.
(Caution) 1. LK-1903B is set to needle thread clamp
prohibited (no motion) with memory
switch U035 at the time of standard deliv-
ery.
2. For the LK-1900BB and 1903BB, memo-
ry switch U035 is enabled at the time of
standard delivery. However, thread clamp
switch is disabled. Also, it is not possible
to set enable/disable of the thread clamp
switch.
Содержание LK-1900B series
Страница 128: ... 114 4 Parts to which grease is applied 1 Work clamp foot lifter area 2 Wiper area Grease JUKI Grease A Grease ...
Страница 129: ... 115 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A ...
Страница 130: ... 116 5 Feed area Grease Grease D ...
Страница 131: ... 117 6 Needle bar and main shaft area 7 Lower shaft area JUKI Grease A JUKI Grease A ...
Страница 132: ... 118 8 Needle thread clamp mechanism area For LK 1900BB 1903BB Grease ...
Страница 133: ... 119 9 LK 1901B relations Grease ...
Страница 134: ... 120 10 LK 1903B relations Grease ...
Страница 135: ... 121 11 LK 1900BB 1903BB relations JUKI Grease A ...
Страница 164: ... 150 4 Power supply circuit diagram Single phase SDC board MAIN board Light blue Orange Brown Yellow Red Black ...