– 112 –
10. Maintenance
(1) Replacing the fuse
DANGER :
1. To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
2. Open the control box cover after turning OFF the power without fail. Then, replace with a new fuse
with the specified capacity.
(2) 100V specification changeover
DANGER :
To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
Insert the jumper connector
❶
(M85236000A0) to
CN14 (2P) of SDC board.
It can be used in AC100 to 120V power supply volt-
age.
In the case of 3-phase specification, supply power to
black and white lines of power cord. (Red line is not
connected.)
(
Caution) When supplying the AC200V power
while inserting the jumper connector
❶
, board breakage will be caused.
The machine uses the following two fuses :
MAIN board
❶
For stepping motor power supply protection
5A (time-lag fuse)
SDC board
❷
For control power supply protection
2A (fast-blow type fuse)
❶
❷
CN14
❶
Содержание LK-1900B series
Страница 128: ... 114 4 Parts to which grease is applied 1 Work clamp foot lifter area 2 Wiper area Grease JUKI Grease A Grease ...
Страница 129: ... 115 3 Thread tension area 4 Thread trimmer area Grease Grease JUKI Grease A ...
Страница 130: ... 116 5 Feed area Grease Grease D ...
Страница 131: ... 117 6 Needle bar and main shaft area 7 Lower shaft area JUKI Grease A JUKI Grease A ...
Страница 132: ... 118 8 Needle thread clamp mechanism area For LK 1900BB 1903BB Grease ...
Страница 133: ... 119 9 LK 1901B relations Grease ...
Страница 134: ... 120 10 LK 1903B relations Grease ...
Страница 135: ... 121 11 LK 1900BB 1903BB relations JUKI Grease A ...
Страница 164: ... 150 4 Power supply circuit diagram Single phase SDC board MAIN board Light blue Orange Brown Yellow Red Black ...