SECTION
PAGE
( 2 )
( 1 )
2 - 1
1
2 - 1 L - Positioner
Checking:
1. Move the needle to the left end by hand.
2. Check if the needle touches the left end of needle hole of needle plate.
Adjustment:
NOTE: Unplug the machine from electrical outlet before adjustment.
1. Remove face cover.
2. Loosen screw (1) and shift needle bar limiter (2) in either direction for
adjustment.
NOTE: * Needle will be broken if needle is outside of left end of needle hole.
NOTE:
* Selector dial can not be turned smoothly if there is clearance over
0.3mm between left end of needle hole and needle.