– 11 –
Adjusting the position of the needle and the throat plate
1. Loosen screws
and adjust the throat plate
so that the needle
enters the center of the needle hole.
Adjusting the clearance between the needle and the needle guide
1. Loosen screw
and adjust so that the clearance between needle
guide
and the needle is 0 to 0.1 mm at the lowest position of the
needle bar.
(Caution) When the needle size is changed, perform readjustment.
1. Adjust the lateral position of needle
and the looper shaft so that
the left side of needle
aligns with section
A
of yoke slide
.
2. The position of york slide
has been factory-assembled so that the
clearance between york slide
and the needle
is longitudinally
0.2 to 0.4 mm and laterally 0 to 0.2 mm when the needle bar comes
to the lowest position. (Move the yoke slide
frontward to adjust the
clearance at the front and rear of the slide.)
3. Adjust the lateral position of yoke slide
by loosening setscrew
and moving yoke slide support A
to the right and left.
4. Adjust the longitudinal position of york slide
by loosening setscrew
and moving york slide cam
longitudinally. The motion timing of
york slide cam
at this time is adjusted by making the engraved
marker line on york slide cam
directly below and tightening the
cam with setscrew
when the needle bar is at the lowest position.
5. Timing of the yoke slide motion is performed in the order that yoke
slide
starts moving from point A to point B immediately after the
blade tip of looper has passed the triangle of the thread.
(Position where the needle bar goes up approximately 6 mm from
the lowest position)
6. Loosen setscrews
in york slide triangle cam
and turn the cam in
the direction of rotation to perform this adjustment.
(Reference) There are electronic pen marks on the yoke slide cam
at factory shipment. Use the marks and the engraved
lines of the yoke slide triangle cam
to adjust timing.
7. Adjust the locus of york slide motion by loosening setscrew
in york
slide cam
and turning the cam in the direction of rotation so that
the locus becomes as shown in the figure.
(Caution) When the needle size is changed, perform re-adjustment.
o Stitch skipping, thread breakage,
or defective thread trimming
(trimming failure and two-thread
cutting) may be caused.
o Stitch skipping or thread breakage
will be caused.
Adjustment Procedure
Results of Improper Adjustment
Adjustment Procedure
Results of Improper Adjustment
Содержание AMB-289
Страница 11: ...7 MEMO...
Страница 16: ...12 5 Wiper adjustment Wiper components 3 to 5mm 6 to 8mm Standard Adjustment...
Страница 18: ...14 6 Adjusting the face plate thread tension A 12mm Standard Adjustment...
Страница 22: ...18 8 Adjusting the position of Y top feed motor Standard Adjustment...
Страница 24: ...20 9 Adjusting the position of Y bottom feed motor Standard Adjustment...
Страница 26: ...22 10 Adjusting the tongue up down cylinder 19mm 5mm Gauge A Standard Adjustment...
Страница 30: ...26 12 Adjusting the differential feed X top feed motor 6 0 5mm Align Standard Adjustment...
Страница 32: ...28 Cloth Tongue Cloth 13 Adjusting the tongue stopper Tongue components marker lineA B B Standard Adjustment...
Страница 34: ...30 14 Adjusting the chuck inversion cylinder 22 0 5mm 15mm Vertical Standard Adjustment 4mm Horizontal...
Страница 36: ...32 15 Adjusting the chuck open close cylinder Standard Adjustment 26 0 5mm...
Страница 42: ...38 16 Adjusting the respective sensors 3 3 C Standard Adjustment 14 5 0 5mm...
Страница 48: ...44 2 Disassembling and assembling of the face plate Procedures of disassembling assembling...
Страница 56: ...52 5 Replacing the main motor Main shaft components B B A Procedures of disassembling assembling...
Страница 58: ...54 6 Replacing the looper rocking base Main shaft components Procedures of disassembling assembling...
Страница 62: ...58 8 Replacing the thread trimmer cylinder 4 5mm Procedures of disassembling assembling...
Страница 66: ...62 10 Replacing and adjusting the thread drawing cylinder 1 to 3mm Procedures of disassembling assembling...
Страница 68: ...64 11 Replacing the thread drawing motor A B C C Procedures of disassembling assembling...
Страница 70: ...66 12 Replacing the loader motor Procedures of disassembling assembling...
Страница 74: ...70 14 Replacing and adjusting the tongue release cylinder 29mm Procedures of disassembling assembling...
Страница 76: ...72 15 Adjusting the moving knife and the fixed knife 1 2 Procedures of disassembling assembling...
Страница 81: ...77 MEMO...
Страница 172: ...168 MEMO...
Страница 176: ...172 MEMO...