8.6.1 TEST MODE ENTRY
Press of the Test button and the following message will appear:
PRESS UP OR DOWN
KEYS UNTIL DESIRED
TEST APPEARS
Press the Up or Down button to cycle among the available tests.
Note:
During the test mode, hitting the Cancel button twice will exit to normal operation. If
there is no activity at the controller for 15 minutes, the unit will return to Manual or
Automatic operation.
8.6.2 HEATER TEST
Press the Up or Down button until the following display appears:
HEATER TEST (DO NOT
RUN DRY):HEATER:OFF
PRESS ENTER TO
CYCLE HEATER STATUS
Pressing the Enter button will turn the heater on.
Pressing the Enter, Up, or Down button
while the heater is on will turn the heater off. The unit will also automatically turn the heater
off after 3 minutes.
Note:
The heater should not be run dry. Running the heater dry may cause damage to the
heaters
.
8.6.3 PUMP TEST
Press the Up or Down button until the following display appears:
PUMP TEST (DO NOT
RUN DRY): PUMP:OFF
PRESS ENTER TO
CYCLE PUMP STATUS
GI-2000 Manual V2.3
Page
36
Pressing the Enter button will turn the pump on. Pressing Enter, Up, or Down button while
the pump is on will turn the pump off. The unit will also automatically turn the pump off
after ~ 1 minute.
Note:
The pump should not be run dry. Running the pump dry may cause damage to the
pump.
8.6.4 TEMPERATURE SWITCH TEST