ENGLISH
M06-001 SET BUZZER
Use Keys
3
and
4
to mute the buzzer when alarms
occur and press Key
5
to confirm and move to the
next page. In this case, no buzzer will sound when
the stove malfunctions.
When finished, the message DONE will be displayed
to confirm correct data entry. Next, the next level
page automatically opens.
MENU 06 - DISPLAY SETTING
Is used to change the display settings and the beep alarm signals of the boiler. Press key 2 to access the pages of the relevant sub-
menus.
M06-002 DELAY IN OFF DISPLAY
Key 3 or 4 to select between ON and OFF mode,
then press key 5 to confirm. In OFF position, the
display keeps being on, while in ON position the
display backlight turns off after 30 seconds of
inactivity.
M07-001 P1 TO LOAD
Press Key
1
or Key
3
to confirm pellet load start.
Once finished loading the main screen is displayed
and shows the sliding message CLEAN BRAZIER
that locks a possible new ignition by preventing the
message to be deleted if not before the boiler door
is open and the excess pellets in the burn pot is
cleaned.
The boiler door must stay opened at least 10”.
MENU 07 - PELLETS LOADING
The MENU07 INITIAL LOAD function is to be used when the pellets tank is fully empty, so once loaded the fuel, it is essential to fill the
burner before switching on again. Press key 2 to access the pages of the relevant sub-menu.
Maximum load time is 100 seconds. This operation
can be interrupted by pressing Key
1
.
The stove door must be opened after loading pellets to make sure there is no excess material in the brazier which,
if this is the case, must be emptied.
THE BRAZIER MUST BE FULLY EMPTY EACH TIME THE STOVE IS TURNED ON.
WARNING
2
1
5
5
1
2
2
1
3 o 4
43
Содержание MEC 21-18 kW
Страница 59: ...ENGLISH NOTE 59...