ENGLISH
07.7
ELECTRIC CONNECTIONS
Connect the 230Vac 50Hz line with the proper cable with plug, supplied with the appliance, which powers up the control unit and all the
appliance’s electrical components.
The stove is fitted with a current socket with fuse, a spare fuse in the drawer and a mains switch. In the event that the control unit does
not switch on, even after turning the switch to “
I
” (ONE), check that the fuse has not blown.
1.
Control unit manual
2.
Earth
3.
Power socket with cord included
4.
Switch
5.
Fuse Ø5X20 F4A 250V IEC 127-II
07.8
ELECTRONIC CONTROL UNIT
The electronic control unit controls all appliance functions and is controlled through the graphic display placed on the front of the boiler
(See CHAP. 08.2 – USER DISPLAY).
The electronic control unit features a timer function with customisable programmes and a user-friendly operating settings. Operations
are controlled by the ROOM PROBE installed at the back of the appliance, that can be prolonged to the installation room in a more
appropriate position to correctly measure room temperature.
FUME TEMPERATURE PROBE
fitted inside the fume exhaust fan
PRESSURE SWITCH
connected to the fume exhaust fan
SAFETY THERMOSTAT
triggers when temperature in the appliance is too high
PELLET TANK SAFETY THERMOSTAT
triggers when burner temperature is too high
The user display lets you use the following main functions:
•
Boiler start and stop.
•
Regulate the desired ambient temperature.
•
Optimise combustion.
•
Manually load pellets into the basket.
•
Manage the timed thermostat to programm the ignition cycles.
•
Report any function irregularities.
•
Indicate the boilers’s operating mode.
•
Regulate the heater element water temperature.
Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/UE
and 2014/35/UE).
WARNING
N F
F
N
2
1
3
4
5
5
29