75
Fault06
Inverter shutdown
and
will
restart
automatically after
malfunction
disappears
DC
input
voltage
higher
than maximum
input voltage of
inverter
Please
check
maximum
output voltage of array and
make sure this voltage is
below
inverter
maximum
input voltage
Fault07
Inverter shutdown
and
will
restart
automatically after
the fault disappears
Input current of
inverter higher
than
rated
maximum value
If this happen, please contact
Supplier.
Fault08
Inverter shutdown
and
will
restart
automatically after
the fault disappears
1. Power
capacity of
pump motor is
higher than
rated output.
2. Pump motor
locked-rotor,
or damaged.
3.Pipe
system
design is not
reasonable
1. Please
inspect
whether
pump motor is normal.
2. Please
inspect
whether
pipeline
system
is
in
accordance with water pump
or not.
3.
Please refer to “
7.4.2.2
Motor parameters
’ setting
by manual
”
4. If this happen frequently,
please contact Supplier.
Fault11
Inverter shut down
Sensor
not
connect proper or
damaged
If this happen frequently,
please contact Supplier.