Table9-3 Malfunction and troubleshooting
Condition
code
Phenomena
Cause value
Troubleshooting
Fault00
Inverter shutdown
and
will
restart
automatically after
the fault disappears
Short circuit in
output wire
Please check if there is short
circuit in output wires
Fault05
Inverter shutdown
and
will
restart
automatically after
the fault disappears
Load higher than
rated
output
power of inverter.
1. Please make sure the
system is proper designed.
The power of pump motor
should not be larger than
inverter output.
2. Make sure that the pump is
working in the well range of
head and flow.
3. Please refer to “
8.3.5.3
Key
Parameters
of
the
System
Set”
to raise the
figure of Imotor.