Malfunction manual reset function: when the mach ine breakdown with
malfunction, can long press "ON/OFF" button, the machine can automatically
restart immediately. W hen the machine is displayed Fault12, no such reset
function.
Fault code and the corresponding meaning are listed below
Table8-12 Malfunction and condition code
LCD showed
code
Name of malfunction and condition
Fault00
Driving over-current.
State01
Array voltage low.
Fault04
Radiator overheating.
Fault05
Output over-load.
Fault06
Array over-voltage.
Fault07
Array over-current.
Fault08
AC over-current.
State09
Dry alarm.
State10
Weak sunshine.
Fault11
Temperature sensor fault.
Fault12
Short circuit fault.
Fault13
Initialization error from the machine .
State14
Overflow alarm.
Fault15
Output phase lose.