51
D-Mode
Dry mode of PV pump system:
“AUTOMATIC” doesn’t need
external water level sensor,
“DETECTION” need external water
level sensor.
OF-F
The optional function of overflow alarm in PV pump system.
On: Inverter has over-flow protection function, If user's solar pump
system include water storage device, this parameter should be
set to "ON".
Off: The inverter has no overflow alarm If the factory setting about
inverter is
“OFF”.
Note: To realize overflow alarm function, there need install
external water level sensor, please refer to “6.6 water level
sensors connect” for detail.
8.3 Main Menu
When the main interface is displayed, press “ENTER”, then enter the main
menu and set or query the detail data, or set the function.
Table8-4 Information list of main menu
Name
Explain
RunInfo
Display running data of inverter.
InverterInfo
Display basic information of inverter.
Statistic
Statistical information of running time data and power inverted .
Settings
Inverter
’s parameter setting.
Fault
Inquiry
Inquire current and historical fault .
ESC
Return to the previous menu .