65
warning. If you want to use this function, please set to “on”.
Default is
“OFF”.
OF-Time
Over-flow alarming recovery time.
MP-Sel
=AUTO Motor parameter self-detection;
=Manual Motor parameter input by manual .
TestOrder
=1 Detect stator resistance;
=2 Detect leakage inductance ;
=3 Detect rotor resistance;
=4 Detect static mutual inducta nce;
=5 Detect dynamic mutual inductance ;
=6 Theoretical calculate mutual inductance .
UIPI-Sel
=AUTO Motor PI parameters
’ self input;
=Manual manual input motor PI parameters .
R-Stat
Stator resistance (m
Ω ), for motor control parameter.
R-Rotor
Rotor resistance (m
Ω ), for motor control parameter.
L-Leak
Motor leakage inductance (mH), for motor control parameter.
L-Mutu
Motor mutual inductance (mH), for motor control parameter.
I-Start
The max. current of soft-start (A), for motor control parameter.
T-UPI
PI accommodation time.
RPM-Limit
Estimated rotate speed limit.
ESC
Return to the previous menu.