96
* = Factory adjusted mode
Trouble shooting
Code C11
Main shaft stop position.
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value.
•
Select Code C11
•
Select one of the following options:
0 = No positioning brake after measuring run.
1*= Positioning brake after measuring run for left plane.
2 = Position brake after measuring run for right plane.
Note
: The selection is permanently acquired.
Code C12
Measuring runs counter.
Example: 222,123 measuring runs completed:
•
Select Code C12
•
Select one of the following options:
1 = Total number of measuring runs completed
2 = Total number of measuring runs where balancing
was successfully completed, indicated by OK
3 = Total number of optimizations or minimizations
4 = Total number of measuring runs in Service mode
5 = Total number measuring runs since last
calibration
Every measuring run completed is saved. Maximum
count is 999,999 measuring runs. Once this number is
reached, the counter is reset to zero. The information
is primarily useful for statistical purposes, for example,
to monitor the endurance of faulty parts, or monthly
(yearly) use of the machine, etc. The measuring
runs performed while the machine is switched on are
transferred to the permanent memory and added when
it is switched off.
Note
: The total counter (option 1) cannot be deleted.