92
* = Factory adjusted mode
Trouble shooting
Option 2
Cancel selection of code C just set and return directly
to the operating mode:
—
Press the
STOP
key twice consecutively.
Note
: Code
C4,
Compensation of the clamping
means, cannot be transferred to the
permanent memory.
Below are the change codes available and the relative
selections possible.
Code C0
Setting operating modes preset by the factory:
•
Select Code C0
•
Select one of the following options:
0* =
No action
1 =
Set the default values
(state 1 appears briefl y)
Note
: The selection is permanently acquired.
Code C3
Selecting unbalance readings in grammes or
ounces, active when the machine is switched on
0* =
Readings in grammes
1 =
Readings in ounces
The selected mode of operation can be transferred to
the permanent memory.
Code C4
Compensation of residual unbalance, if any, in the
clamping means.
High precision measurement.
Every time the clamping means are substituted,
compensation must be deleted or carried out again
with the new means fi tted.
Resetting the operating state to 0 cancels the clamping
means compensation.
The compensation is also cancelled following:
- balancer calibration or recalibration,
- unbalance optimization,
- balancer switch off.
•
Select Code C4
•
Select one of the following options:
Содержание MIX-2