SECTION 4 - MACHINE OPERATION
3121783
4-3
Electric Engine Starting Procedure - AC Voltage Machine
ENSURE THE ELECTRICAL CIRCUIT BEING USED IS THE SAME VOLTAGE AND
FREQUENCY INDICATED ON THE ELECTRIC ENGINE PLATE. USE AN AC EXTEN-
SION CORD WITH SUFFICIENT AMPERAGE CAPACITY TO PROPERLY POWER
THE MACHINE.
1. Before connecting the machine to the electrical
circuit, ensure the key on the diesel engine is in the
OFF position.
2. Power the machine using a heavy duty AC power
cord with sufficient amperage capacity, through
the connector (
1
) positioned near the electric
engine.
3. Turn on the circuit breaker switch (
2
) positioned
behind the clear plastic cover near the electric
engine (— symbol is ON, O symbol is OFF).
4. Start the electric engine using the electrical engine
start button on the platform control box.
(item 5 -
Figure 4-1.)
and operate machine.
5. When finished operating with the electric engine,
turn off breaker switch (
2
), and unhook the electric
AC cord from connector (
1
).
2
1
OL00570