SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3-14
3121783
8.
Selector Button
Used for selecting an item when the Service Menu
button (
6
) is pressed.
This button is also used as the SkyGuard™ Override
switch. When the SkyGuard™ system is engaged,
press this button to override and disengage Sky-
Guard™.
9.
Track Width Adjust
This control allows the operator to narrow the
track.
10.
Power/Emergency Stop
A two-position red switch removes power from the
ground controls when pushed in. Twist the switch
clockwise to allow for machine operation at the
ground control station.
11.
Go Home
Holding this button in allows the operator to
return the MEWP to the fully closed position. The
machine will determine and perform the neces-
sary maneuvers to bring to boom down to the
closed position.
12.
Diesel Engine Starter
This button allows the operator to start or stop the
diesel engine. Holding this button in allows the
operator to pre-heat the diesel engine in cold cli-
mates.
13.
Electric Engine Start
This button allows the operator to start or stop the
electric engine.
NOTE:
Controllers (
14
through
21
), the speed of component
movement is proportional to the controller distance
from the center neutral position.
14.
Left Side Track Drive And Steer
This control when moved forward or rearward
simultaneously with the right side track control
(21), allows the operator to move the machine in a
straight forward or reverse direction. If each con-
trol is moved individually, different amounts or in
opposite directions steering the machine occurs.
15.
Tower Boom Lift
This control allows the operator to raise and lower
the tower boom.
16.
Main Boom Lift
This control allows the operator to raise and lower
the main boom.
Movement of a controller without first
pressing the platform footswitch is indi-
cated by the depress footswitch error
icon on the platform/remote LCD dis-
play.