SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3121783
6-23
MICROROPES
ON position indicates both cables are working.
START M. TE
ON position indicates the engine start button (from ground) is
pressed.
MOTOR TEMP.
OFF position with the engine running indicates the alarm is
activated.
MOTOR PRESS.
ON position with the engine running indicates the alarm is
activated.
START M. EL
ON position indicates the remote control from ground is acti-
vated by the provided key.
MICROJIB A
Both ON indicates the JIB arm is completely closed.
MICROJIB B
PEDALE
ON position indicates the pedal within the basket is pressed.
(only pedal version)
EM BASK. A
Both ON indicates the emergency STOP (of the remote control)
within the basket isn't pressed
EM BASK. B
POSM 1 A
Both ON indicates the stabilizer 1 is in stabilization position.
POSM 1 B
POSM 2 A
Both ON indicates the stabilizer 2 is in stabilization position.
POSM 2 B
POSM 3A
Both ON indicates the stabilizer 3 is in stabilization position.
POSM 3B
POSM 4A
Both ON indicates the stabilizer 4 is in stabilization position.
POSM 4B
R.C. PLATFORM
ON position indicates the remote control is in its mount. (in the
platform).
INCLIN. X
Indicates the inclination of X axis in tenths of a degree.
INCLIN. Y
Indicates the inclination of Y axis in tenths of a degree.
LOAD
Indicates the weight in the platform in pounds.
POS. 1E2
Indicates 1° and 2° arm cylinder stroke in tenths of a millime-
ter.
POS. 3
Indicates 3° arm cylinder stroke in tenths of a millimeter.
ROTATION A
Indicates the angular position of the aerial part in degrees
(180° - aligned photocells).
MOTOR RPM
Indicates the engine speed.
CURRENT A
Indicates the power to proportional valve.
CURRENT B
Indicates the power to proportional valve.
CURRENT C
Indicates the power to proportional valve.
TEMPERAT.
Indicates the temperature measured by the electrical probe.
SUPPLY (V)
Indicate the voltage (In volts).
To