Servomotor series JHN, JHQ, and JL – User Manual
Product description
Jetter AG
32
Y
Resolver, 2-pole, safely mounted
F2S
JL series: HIPERFACE
®
, singleturn, size 2 = SKS36 S; from size 3 = SRS50 S
F3S
JL series: HIPERFACE
®
, multiturn, size 2 = SKM36 S; from size 3 = SRM50 S
F13S
JHN and JHQ series: HIPERFACE
®
, singleturn SKS36 S (from size 2)
F14S
JHN and JHQ series: HIPERFACE
®
, multiturn SKM36 S (from size 2)
F15S
JHN and JHQ series: HIPERFACE
®
, singleturn SRS50 S (from size 3)
F16S
JHN and JHQ series: HIPERFACE
®
, multiturn SRM50 S (from size 3)
F17S
JHQ series: HIPERFACE DSL
, singleturn EES37 S (in preparation)
F18S
JHQ series: HIPERFACE DSL
, multiturn EEM37 S (in preparation)
F19S
JHN and JHQ series: HIPERFACE DSL
, singleturn EKS36 S (from size 2)
F20S
JHN and JHQ series: HIPERFACE DSL
, multiturn EKM36 S (from size 2)
13: Potentially explosive areas
JHN 3 - 0250-045-6 R V B P S-X C F
E
L K X
E
Potentially explosive area (frame sizes 2 ... 8 are possible)
E1
Potentially explosive area, ATEX (zone 2) II 3 G EEx nA II T3
14: Bearings
JHN 3 - 0250-045-6 R V B P S-X C F E
L
K X
L
Bearings
L1
Reinforced bearings at D end
15: Cooling
JHN 3 - 0250-045-6 R V B P S-X C F E L
K
X
_
Natural air cooling (standard design)
K1
Forced ventilation at ND end
16: Further options
JHN 3 - 0250-045-6 R V B P S-X C F E L K
X
X
Further options
Notes on operating the motors on safety controllers
3.4.8
When motors with resolvers are used in combination with safety controllers, e.g. Jetter Safety
Control JSC, there is the option
Y - Safe encoder mounting according to EN 61800-5-2, Table
D.16
.
The MTTFd value is 140,000 hours at an ambient temperature of the motor of 60°C.
For the HIPERFACE encoder in safety design, the type designation is supplemented by the
additional specification
S
for option
Fxx
(encoder type). For the EKM 36 S HDSL encoder, for
example, this would be the order code F20S