Servomotor series JHN, JHQ, and JL – User Manual
Installation and commissioning
Jetter AG
217
JHQ12, JHQ22 and JHQ24 motors
8.6.1
These motors use the HIPERFACE DSL
®
as encoder. The following table shows the pinout of the
motor connector with M17 quick release:
Front view
Pin
Signal
Orange, 9-pole,
pins
Connector
I-Tec
A
Phase 1
B
Phase 2
C
Phase 3
PE conductor
1
Brake+
2
Brake-
3
DSL+
4
DSL-
5
DSL shield
Avoid contact between the DSL shield and the all-
over shield.
Attach the DSL shielding to the motor (pin 5) and
to the respective pin of the servo amplifier.
Housing
Place the all-over shielding and the brake
shielding on the connector housing.
All other motors
8.6.2
These motors use the HIPERFACE DSL
®
as encoder. The following table shows the pinout of the
motor connector with M23 quick release:
Front view
Pin
Signal
9-pole, pins
Connector
M23
A
Phase 1
B
Phase 2
C
Phase 3
PE conductor
G
Brake +
F
Brake-
E
DSL+
H
DSL-
L
DSL shield
Avoid contact between the DSL shield and the all-
over shield.
Attach the DSL shielding to the motor (pin L) and
to the respective pin of the servo amplifier.
Housing
Place the all-over shielding and the brake
shielding on the connector housing.