113
When using LINAX
®
linear motor axes and ELAX® electric
slides, we suggest executing the Quick Start function with
automatic system-check.
Test of brushless servo motors for hall signals encoder
A/B and motor phase (wiring and colors).
There is no common standardization for servo motor
connectors. Jenny Science is happy to support you
during the setup process.
Test if motor is running at low velocity
With WebMotion®
Menu Motion:
S-CURVE 20%
AC (x1‘000) 100
SPEED 10’000
Power
Rep Reverse 10’000
Menu Terminal:
SCRV20
AC100000
SP10000
WA10000
PWC
RR100
15.3
Notes for Error 89
The error 89 shows a critical SMU error, which cannot be deleted by a command. The source of the error has first
to be cleared and then the XENAX has to be restarted in order to delete the error. The description of the error is
shown in WebMotion. If the error cannot be cleared or if the error occurs multiple times, please contact Jenny
Science.
Click on the Button „ERROR 89“ and the window
would be open.