43 16021730 Rev. 0
OUT
IN
SERVICE TEST
18
FORCE
DEFROST
SERVICE TEST
19
FRESH FOOD
FAN SPEED
SERVICE TEST
20
FREEZER
FAN SPEED
SERVICE TEST
21
FRESH FOOD
Thermistor
VALUE
SERVICE TEST
22
FREEZER
Thermistor
VALUE
SERVICE TEST
23
AMBIENT
Thermistor
VALUE
SERVICE TEST
24
EVAPORATOR
Thermistor
VALUE
Unit will initiate a defrost, exit service mode, and resume normal
operation mode.
PI - START & STOP TEST
Display will not show test results.
Display is in revolutions per second. Range 36 - 42 average.
PI - START & STOP TEST
DISPLAY
SPEED - FAN SHOULD BE OPERATING
Display is in revolutions per second. Range 42 - 50 average.
PI - START & STOP TEST
DISPLAY
SPEED - FAN SHOULD BE OPERATING
Ensure that temperature is in appropriate range.
PI - START & STOP TEST
DISPLAY
Will display fresh food thermistor
temperature. (e.g. 13 72 is 137.2 degrees.)
Ensure that temperature is in appropriate range.
PI - START & STOP TEST
DISPLAY
Will display fresh food thermistor
temperature. (e.g. 13 72 is 137.2 degrees.)
Ensure that temperature is in appropriate range.
PI - START & STOP TEST
DISPLAY
Will display fresh food thermistor
temperature. (e.g. 13 72 is 137.2 degrees.)
Ensure that temperature is in appropriate range.
PI - START & STOP TEST
DISPLAY
Will display fresh food thermistor
temperature. (e.g. 13 72 is 137.2 degrees.)
Содержание Luxury Series
Страница 13: ...13 16021730 Rev 0 Refrigerant Flow Side by Side Refrigerant Flow Diagram ...
Страница 14: ...16021730 Rev 0 14 Cabinet Air Flow Side by Side Cabinet Air Flow Diagram ...
Страница 16: ...16021730 Rev 0 16 Water Valves Diagram Bottom View Back View Primary Valve Secondary Valve Filter Head Bypass ...
Страница 46: ...A 1 ...
Страница 72: ...B 1 Appendix B ...