Scope
This document covers Ethernet testing procedures used for Business Services customer activation,
fault isolation, and troubleshooting using the JDSU T-BERD 6000A portable business services tester.
This document provides procedures for Metro Ethernet service up to 1 Gbps, including:
Layer 2 and Layer 3 IPv4 RFC-2544 tests between two T-BERD 6000A’s
Layer 2 and Layer 3 IPv4 RFC-2544 tests between the T-BERD 6000A and T-BERD 5800
Layer 2 and Layer 3 IPv4 RFC-2544 tests between the T-BERD 6000A and HST-3000
Layer 4 RFC-6349 TCP Throughout tests between two T-BERD 6000A’s.
RFC-2544 is a recommended test suite for verifying key performance indicators or Metro Ethernet
service with a single class of service
RFC-6349 is a recommended test suit for verification of TCP Throughput on Metro Ethernet networks.
This document mandates proper care, cleaning, inspection, and handling of fiber optic connectors. All
fibers and connectors must be cleaned and inspected when service is turned up on these fibers and
whenever a fiber is disconnected and reconnected.