- 11 -
3.6 Mounting the devices
ATTENTION: Allow a fixture distance of at least 0.5 metres from easily flammable
material and the distance between the light emission and the surface to be illuminat-
ed must be at least 2.0 meters.
!
The Sparx 12 can either be placed or suspended from a truss system in any position.
ATTENTION: Mounting horizontally to the truss system is only permitted if the omega
brackets are attached to the outer camlocks. (distance 213.20mm).
If you place the device on the ground, only operate the device on a hard surface, as the air inlets
in the foot must remain free!
Name
Erstellt
Art.-Nr.:
Datum
Prisma
Fax.: 07304 / 9617-99
Tel.: 07304 / 9617-0
Sparx 12
utobuschat
Allgemeintoleranzen
ISO 2768-m
Blechdicke:
Material:
Farbe:
Oberfläche:
Abmessung:
Lichtanlagentechnik GmbH
Sallersteig 15, 89134 Blaustein
12
37
6,
8
49
0,
9
248,7
220
140
213,2
14
0
To hang the device on a truss system, use the JB-Lighting Omega-Clamps with Camloc
connectors. The Omega clamps can be mounted in the following four ways:
The Camlocs must snap in to be locked properly. Ensure that the structure (for example a truss
system ) to which you are attaching the fixture is secure. If you install the fixture to a hanging
system (for example to a truss system) always attach a safety cable, that can hold at least 10
times the weight of the fixture. There is a corresponding eyelet on the fixture for the secondary
safety device (see picture).
1
2
4
3
eyelet for the secondary
safety device